E-24 Life/form® Child S.A.L.A.D. Simulator • Suction Assisted Laryngoscopy and Airway Decontamination (S.A.L.A.D.) simulator uses suction to enhance first pass success-laryngoscopy (FPS-L) with a non-anesthetized patient in active emesis • Simulates a non-anesthetized patient for practicing intubation, ventilation, and suction • Practice oral, digital, and nasal intubation, as well as E.T., E.O.A., P.T.L, L.M.A., Combitube®, and King System insertion • Permits suction techniques, and proper cuff inflation with active emesis • Anatomy and landmarks include teeth, tongue, oral and nasal pharynx, larynx, epiglottis, arytenoids, false cords, true vocal cords, trachea, esophagus, and cricoid cartilage • Offers room to maneuver and a slightly anterior position, making the simulator great for introductory classes as well as advanced students • Apply cricoid pressure to change the position of the trachea and close the esophagus • Rigid suction catheter distracts lower mandible and tongue to permit laryngoscope insertion • Realistically practice the Sellick maneuver • Manual carotid pulse • Includes Child Airway Management Trainer Head, suction canister with 2 right angle tubing adapters, gallon container with hand pump, 2 simulated latex-free lungs, thickener, rigid suction catheter, two 3-ft. lengths of clear vinyl tubing, pump spray lubricant, 5 red caps with white fittings, tubing couplings, 6 pinch clamps, #10 spanner bit, neck ring with 2 wing nuts and 2 plastic- headed thumb screws, neck adapter with 2 plastic-headed thumb screws, safety cap, case handle with 2 pins, and carrying case with telescoping handle • 5-year warranty LF03506U Sh. wt. 22 lbs. SSCOR VX-2® Flat Back Suction Unit • Performs a full range of suction procedures • Adjust negative pressure to any point between <50 mmHg to >525 mmHg • Suction canister is well protected yet easily accessible • IPX4 rated for resistance to ingress of fluids • Internal battery care system with external indicators • Ramps up incoming current to fully charge the battery • Provides a float charge when the battery is fully charged to avoid overcharging • Disconnects a depleted battery to avoid destructive deep discharge • LED indicators on front panel show battery condition • Sealed lead acid battery makes replacing the battery affordable • Not recommended for hospital use • Includes DC cable, AC/DC converter, canister, 69/16-ft. (2 m) patient tube, Hi-D® suction tip, and CD manual • Included charger will only charge the battery purchase Universal Input Charger below to power the unit while operating in lieu of the battery • 17 in. L x 51/4 in, W x 9 in, H SB52301U Sh. wt. 16 lbs. Universal Input Charger • 100-240V AC SB52300U Sh. wt. 1.25 lbs. Tubing Replacement Kit • Includes two 3-ft. lengths of clear vinyl tubing, 2 tubing couplings, 6 pinch clamps, 2 open red caps with white adapters, 3 closed red caps with 2 white adapters, and four 2 in. L plastic tubes LF03507U Sh. wt. 1.25 lbs. Replacement Lungs • Set of 2 LF03508U Sh. wt. 0.50 lbs. Life/form® S.A.L.A.D. Simulator • Suction Assisted Laryngoscopy and Airway Decontamination (S.A.L.A.D.) simulator uses suction to enhance first pass success-laryngoscopy (FPS-L) with a non-anesthetized patient in active emesis • Simulates a non-anesthetized patient for practicing intubation, ventilation, and suction • Practice oral, digital, and nasal intubation, as well as E.T., E.O.A., P.T.L, L.M.A., Combitube®, and King System insertion • Permits suction techniques, and proper cuff inflation with active emesis • Anatomy and landmarks include teeth, tongue, oral and nasal pharynx, larynx, epiglottis, arytenoids, false cords, true vocal cords, trachea, esophagus, and cricoid cartilage • Offers room to maneuver and a slightly anterior position, making the simulator great for introductory classes as well as advanced students • Apply cricoid pressure to change the position of the trachea and close the esophagus • Rigid suction catheter distracts lower mandible and tongue to permit laryngoscope insertion • Realistically practice the Sellick maneuver • Manual carotid pulse • Includes “Airway Larry” Adult Airway Management Trainer Head, suction canister with 2 right angle tubing adapters, gallon container with hand pump, 2 simulated latex-free lungs, thickener, rigid suction catheter, two 3-ft. lengths of clear vinyl tubing, pump spray lubricant, 5 red caps with white fittings, tubing couplings, 5 pinch clamps, #10 spanner bit, and carrying case with handle • 5-year warranty LF03500U Sh. wt. 22 lbs. Rigid suction catheter distracts lower mandible and tongue to permit laryngoscope insertion. Rigid Suction Tool LF03501U Sh. wt. 0.38 lbs. Suction Canister LF03502U Sh. wt. 2.50 lbs. Gallon Container with Hand Pump LF03503U Sh. wt. 2 lbs. Replacement Lungs LF03504U Set of 2. Sh. wt. 0.56 lbs. Replacement Kit Includes two 3-ft. lengths of clear vinyl tubing, tubing coupling, 5 pinch clamps, and 5 red caps with white adapters. LF03505U Sh. wt. 1.25 lbs. Laryngoscope not included. Airway Management Training